产品中心

PRODUCTS

动植物组织透明化试剂
Visikol HISTO-M 3D细胞球体透明化试剂
Visikol HISTO-M 3D细胞球体透明化试剂


visikol HISTO-M是一种用于三维细胞培养模型(类器官、球状体、微组织)透明化处理的试剂盒,具有无损、快速、易用等优点。

在线咨询

Countevery cell in your 3D model with Visikol HISTO-M


visikol HISTO-M是一种用于三维细胞培养模型(类器官、球状体、微组织)透明化处理的试剂盒,具有无损、快速、易用等优点。

· 适用于厚度小于1mm的样品 

· 可兼容免疫染色

· 透明化过程可逆,可继续下游分析处理


While 3D cell culture models are being adopted in the drug discoveryspace for their improved in vivo relevancy, the imaging techniquesused to characterize these models have serious room for improvement. Theproblem is due to the thickness and opacity of the 3D cell culture models. Sincethey are too thick, light cannot penetrate to the center of the tissues, and soonly the outer 2-3 layers of cells can be detected.  This causes the darkcenters often seen in images of 3D cell culture models. Unfortunately, thiseffect introduces bias into results, since only the outermost cells can bedetected, and those cells are the most exposed to oxygen, nutrients, and drugcompound. Treatment with Visikol HISTO-M solves this problem.

 


应用案例

共聚焦成像

Clearing with Visikol HISTO-M renders the 3D model transparent, allowingfor the detection of every single cell using confocal imaging with a HighContent instrument.

 


NCI-H2170 spheroids approx 250 um in diameter labeledwith nuclear stain. Left is in PBS and right is the same spheroid afterclearing with Visikol HISTO-M.

 

3D cellculture in PBS, not cleared. A large majority of cells are not observable.


3D cell culture after clearing withVisikol HISTO-M - every cell in the model can be detected

Number ofcells characterized in before and after clearing NCI-H2170 3D cell culturemodel

Resultsare clear with Visikol HISTO-M!


高灵敏度,少实验误差

Significant differences between cleared and non-cleared tumor spheroidshave been observed in the dose response curves of commonantiproliferatives. The application of tissue clearing to 3D cell culturecharacterization has been shown to increase sensitivity to measure doseresponse by an order of magnitude due to the increased number of cells detectedin cleared spheroids. Furthermore, highly significant differences in doseresponse are measured between cleared and non-cleared tumor spheroids due tothe increased level of proliferation in the outermost cells.

NCI-H2170spheroids dosed with cisplatin and evaluated for cell proliferation (Ki67positive cells); A) Dose response relative to vehicle control; B) Absolute cellproliferation score

 

Visikol组织透明化及免疫荧光标记试剂盒宣传册.pdf


注:该产品用于临床前科研实验





了解更多产品信息,请联系

电话:+86-21-37827858

邮件:info@nuohailifescience.com


应用案例

共聚焦成像

Clearing with Visikol HISTO-M renders the 3D model transparent, allowingfor the detection of every single cell using confocal imaging with a HighContent instrument.

 


NCI-H2170 spheroids approx 250 um in diameter labeledwith nuclear stain. Left is in PBS and right is the same spheroid afterclearing with Visikol HISTO-M.

 

3D cellculture in PBS, not cleared. A large majority of cells are not observable.


3D cell culture after clearing withVisikol HISTO-M - every cell in the model can be detected

Number ofcells characterized in before and after clearing NCI-H2170 3D cell culturemodel

Resultsare clear with Visikol HISTO-M!


高灵敏度,少实验误差

Significant differences between cleared and non-cleared tumor spheroidshave been observed in the dose response curves of commonantiproliferatives. The application of tissue clearing to 3D cell culturecharacterization has been shown to increase sensitivity to measure doseresponse by an order of magnitude due to the increased number of cells detectedin cleared spheroids. Furthermore, highly significant differences in doseresponse are measured between cleared and non-cleared tumor spheroids due tothe increased level of proliferation in the outermost cells.

NCI-H2170spheroids dosed with cisplatin and evaluated for cell proliferation (Ki67positive cells); A) Dose response relative to vehicle control; B) Absolute cellproliferation score


©Copyright 2017 锘海生命科学 沪ICP备17032315号